Refurbishing
Refurbishment of 500 KW General Electric condensing turbine
- Grinding of journal areas.
- Rebabitting of journal & thrust bearings.
- Manufacture of new HP & LP gland segment
- Overhauling of governor & governor valve assembly.
- Overhauling of oil pumps and other related auxiliaries.
- Dynamic balancing of turbine rotor as per ISO 1940, grade 1,0.
- Condenser cleaning & hydro test of the same.
- New control panel for auto start of the auxiliary oil pump.
- Erection & commissioning of the TA set.