Upgradation, refurbishing, erection & commissioning of Bellis & Morcom make 1,5 MW steam turbo- alternator :
- Inlet steam temperature increased from 35 kg/cmsq to 42 kg/cmsq.
- Backpressure reduction from 3,5 kg/csmq to 1,5 kg/cmsq.
- Refurbishing & dynamic balancing of the pinion, gear & turbine rotor.